Baxi condensate trap leaking. However, please excuse me if this.
Baxi condensate trap leaking. View and Download Baxi Main Combi 24 HE installation and service instructions manual online. Mar 21, 2015 · I've got a leak that appears to be from the condensate trap. we can't get in touch with the installers at all so my Brother is paying to get it In this edition of Training Tuesday, Baxi trainer Justin shows you how to remove the condensate plug before installation on the Baxi 800/600 Combi 2 range. Condensation trap issues: Baxi boilers, especially combi models, have condensate traps that collect water vapour during operation. Oct 24, 2024 · Discover how a furnace condensate trap works to manage water efficiently within heating systems. Solo 12 HE boiler pdf manual download. Seen loads of these traps on Ebay for £18, is it worth replacing it? Boiler was turned off for several weeks, but this leak has appeared Manuals and User Guides for Baxi Combi 636. Explore our range of spares for related appliances to find the perfect match. Also for: Promax 24 sl, Promax 30 sl, Promax sl series, Promax 12 sl, Promax 15 sl, Dec 25, 2013 · Hi, I need to replace the condensate pipe on a baxi duo tech. View and Download Baxi 100 He installation and servicing instructions online. This was sorted. llowing free flow of condensate. Do I just pull it out of that and push the new one in? Just want to make sure before I yank it out. The condensate trap and/or drainage pipe is blocked. Baxi Luna HT Troubleshooting Guide Note: It is recommended that a combustion analyzer test be performed at every visit and that the proper adjustments are made if necessary. ) during appliance operation and service (circulator replacement, condensate trap, control replacement, The condensate trap is rectangular and has seperate chambers, the left hand side is half full and the right hand side appears to be empty. The boiler is Worcestor Bosch Junior 28i. Verified purchase: YesCondition: NewSold by: adlinkuk by eventersworld Oct 14, 2020 May 28, 2025 · Baxi boilers are trusted by homeowners for their performance and reliability. There is a leak from a connection inside the boiler. Whether you're dealing with a boiler, air conditioning unit, or any other system that produces condensate, this kit meets your needs. High-efficiency wall-hung condensing gas boiler. Dec 17, 2013 · Have now looked at the manual and seems I can drain the condensate trap from the drain plug (not surprising if you know what this is). Fill the condensate trap assembly. I’m quite convinced that it is leaking pipework as I have done the following Place a balloon over the overflow pipe (copper) for a week, no signs of water from here. Won’t cause the pipe to leak though, unless hot water causes condense pipe joints to fail somehow. 1X BOILER CONDENSATE TRAP. Replaced cracked and leaking trap that was 15yrs old and came with the boiler. The boiler shall be installed such that the gas ignition system components are protected from water (dripping, spraying, rain, etc. When I removed the front cover from the upper compartment, I noticed condensation forming at the top near the intake air and exhaust View and Download Baxi 105 HE installation and servicing instructions online. Be prepared this winter. 600 Combi 2 Series boiler pdf manual download. Mar 2, 2025 · Learn how to clean an Ideal Logic boiler condensate trap from a full-time heating engineer. 100 He boiler pdf manual download. Inspect the Furnace’s Internal Components Check the condensate trap, a small U-shaped Dec 27, 2023 · Fixing the fit of the condensate drain pipe is an effective fix for this particular problem. The Heatxchange are suppliers of GENUINE Baxi parts and spares. Watch this video to learn how to thaw a frozen boiler condensate pipe. A faulty condensate pipe can not only cause your boiler to malfunction but even stop working entirely. If you’re asking ‘why is my boiler leaking?’ May 21, 2020 · Hope someone can help few weeks back I posted about my Mum's Baxi Boiler leaking and got told the condensate has been connected before the trap. Jul 25, 2012 · Hi all The plastic condensate pipe from my boiler is leaking. This article explains its critical role in preventing gas leaks, maintaining safety, and enhancing furnace performance. Get insights on common causes, symptoms, and effective maintenance tips. If you need some help or advice for your boiler please get in touch. We aim to keep prices low and supply your replacement Baxi 5122199 CONDENSATE TRAP ASSY for next day delivery so you can complete your repair. I removed the trap and there was a tiny split in the condense trap on the rear corner. We aim to keep prices low and supply your replacement Baxi 710009302 CONDENSATE TRAP BOWL for next day delivery so you can complete your repair. I understand I am legally not allowed to do this but surely looking around can't View and Download Baxi POTTERTON Performa 24 Eco HE installation & service instructions manual online. Therefore, it’s important to schedule routine testing of your steam traps. The thing, is would condensate be condensed water from the atmosphere? As I see the water in that drip tray and in the plastic condensate container is yellow ish and looks like it came from the heating system water - it looks like the water I saw around when they changed the pump. A few odd jobs from last week including a leaking condensate trap and failed flue seals on a BAXI solo causing high levels of carbon monoxide inside Jun 12, 2024 · Potterton condensate trap Replaced cracked and leaking trap that was 15yrs old and came with the boiler. In the absence of an authority, PVC and CPVC pipe must comp y with ASTMD1785, F441 or D2665. It appears to have a crack in the plug which is probably from overtightening. Check Vent Condensate Drain System ning, check the discharge end of the condensate drain tubing. Aug 9, 2024 · POTTERTON PERFORMA 24i HE 30HE & 24 ECO HE 5111978 BOILER CONDENSATE TRAP. proudly provides HVAC services to the North Georgia area including: Atlanta, Canton, Woodstock, Marietta, Cumming Customer: I have a boiler that recently started leaking rusty-colored water from the bottom. See full list on fantastichandyman. The existing one is fitted inside what looks like a flexible black rubbery type pipe coming out of the boiler. With step-by-step instructions and videos. Typically between 1- 1. Dec 7, 2023 · In this article, I’ll tell you what you should do if your furnace’s drain line gets clogged. Start by checking whether this is the cause behind the furnace leaking water: Locate the condensate assembly in your furnace. Jun 4, 2024 · Potterton condensate trap Replaced cracked and leaking trap that was 15yrs old and came with the boiler. Leaking Combi Boiler. You can isolate the heating circuits under the boiler and see if the pressure indicated on the boiler goes down. I'll try that and watch for more puddles. Baxi 710006502 CONDENSATE TRAP BODY. Browsing Baxi Condensate TrapsShowing 1 - 21 of 102 Results View the thread, titled "Baxi 100 HE condensate trap causing flame failure" which is posted in UK Plumbers Forums on UK Plumbers Forums. It should be after, thats why it was backing up into the boiler. JA: Do you know the model of your Baxi pipe? How old is it? Customer: The boiler was fitted in 2009. Note: Use materials approved by the authority having This condensate trap kit is suitable for various applications, including residential and commercial systems. Condensing Combination Boiler. Also for: 800 system 2 24, 800 system 2 30. This small plastic pipe may seem like a minor issue, but that doesn’t mean you ignore it. Things to check for first. Developed with Baxi Heating UK Limited. We have 3 Baxi Combi 636 manuals available for free PDF download: Installation And Service Manual, User Manual Plumbers Videos. I recently replaced the drain line from the furnace vent to the trap because the original rubber hose deteriorated and was leaking. Mine seems quite different than the most common leaking problem other people have had (due to clogged condensate trap). Oct 30, 2015 · http://tandnservices 770-490-5595 T&N Services LLC. When the boiler is pressurised the water seems to leak out through the condensate drain. Inspect the Condensate Pump (if applicable) High-efficiency furnaces may use a pump to move condensation to a drain. Ensure the discharge of condensate complies with any national or local regulations in force (see British Gas “Guidance Notes for the Installation of Domestic Gas Condensing Boilers” Jul 19, 2024 · Potterton condensate trap Replaced cracked and leaking trap that was 15yrs old and came with the boiler. Main COMBI 24 HE. 2. Verified purchase: YesCondition: NewSold by: adlinkuk by eventersworld 14 Oct, 2020 Sep 26, 2020 · Got a potterton promax he with a leak coming from the drain plug on the condensate trap. I sure with a daily top-up that I would have noticed by now if I had a leak under the floorboards. It looks like water is coming out between the pvc pipework and the nut into the bottom of the boiler. CAUTION The condensate line must remain unobstructed, allowing free flow of condensate. Dec 10, 2024 · Learn how to clean your furnace condensate trap and keep your heating system running efficiently. When the trap gets blocked, the water has nowhere to go — leading to leaks. d situation till replaced ,anybody else had same fault as baxi not aware of problem. On the point about condense pipes freezing - it would be possible for the pipe or Mar 8, 2009 · As said above, it'll be corrugated tube which drains condensate from comb chamber into trap. Dec 13, 2008 · I have a Baxi Solo 30 boiler that runs a pressurised heating and hot water system . All. However, please excuse me if this Housewarm Jul 25, 2025 · Learn to fix furnace condensate drain trap leaks and prevent water damage. Take a look at where the drain pipe connects to the trap. Also for: Main combi 30 he, Combi 105 he. The older ones of these had a problem with the heat exchanger plugs leaking at the back of the heat exchanger, big job though. Videos sent in from a Plumber in the UK. Baxi COMBI INSTANT HE 105. Ensure your furnace operates at peak performance and save on utility bills Baxi 5122199 CONDENSATE TRAP ASSY. May 30, 2012 · The leak was coming from the condense trap, but could not be seen. Is the leak constant, and at a steady rate? If it happens only when the burner is on then it's scenario (1) above. This comprehensive guide covers the importance of maintenance, tools needed, and a step-by-step process for cleaning. Jan 2, 2017 · The condensate pipe goes through wall and into a soil pipe I think. Note: Use materials approved by the authority having As title suggests :) #plumber #boiler #tradesman #apprentice Apr 13, 2010 · I have a Baxi 130HE Condensate trap looks to have grey/white powdery blockages. I provide a repair service for Vaillant boilers such as the ecoTEC Pro mentioned in this post. Baxi COMBI INSTANT HE 80. Trust Quality Cooling & Heating for reliable HVAC and plumbing solutions. The leak (just a slight but constant drip) is located where the pvc meets the trap's drain stub (at least that what I think Jan 17, 2013 · My Baxi 105HE, is needing an almost daily top up and my condensate pipe (NOT PRV) seems to be dripping more than it probably should. 22 fault, the pressure had dropped to 0. Wall Mounted Powered Flue Condensing Boilers Gas Fired Central Heating Units. Now whenever I test it the water pressure drops pretty much straight away and I get a flame failure. 5 bar What is pressure rising to when heating on Check out my new video • HOW TO MOVE A RADIATOR - Step by Step Gui Leaking combi boiler in Menston Leeds. I’ll also discuss what causes a drain line to get clogged in the first place– so you can prevent it from happening again! Baxi 710009302 CONDENSATE TRAP BOWL. When the water level reaches a certain point, a float inside triggers a switch to expel the water. Whether you have a combi, system, or heat-only boiler, you may occasionally see Baxi fault codes appear on the boiler’s display. With more than 25 years of experience servicing European boilers in BC’s unique climate, we provide fast response, transparent pricing, and solutions that are fully compliant Dec 12, 2009 · I'm presuming you're on about the condensate trap. Baxi COMBI HE 105. Fo Jul 22, 2017 · I always inspect the condensate trap and usually drain it at the yearly inspection, this removes most of the sediment from it, which, sadly, is the heat exchanger being slowly eaten away! If it is really bad then I remove it and thoroughly clean it out. My name's Allen Hart, today we're with Mackie repairing a leaking Baxi. Is this something I can fix myself? I am tempted to remove the boiler casing just to see if I can identify exactly where the leak is coming from. I now perform a yearly service myself as these boilers really do need looking after. Cement and Hi there, Baxi 618 System boiler just installed. The PRV is letting out water and there is leaky connection on its outlet. That is the condensate trap you are describing. If the flue is pointing 1. This guide Oct 27, 2024 · The condensate trap is rectangular and has seperate chambers, the left hand side is half full and the right hand side appears to be empty. Gas Fired Wall Mounted Condensing Boiler. Jan 26, 2021 · Want to find out about Baxi Boiler Problems and Repairs? Our free guide gives you all you the information you need plus the option of free boiler quotes. Nov 2, 2006 · in the last 2 weeks i have visited two propertys for reported water leak from the boiler. both have been main he combi,s and the condesate trap has broken on the top side as the hose connects,resulting in i. Oct 28, 2022 · I have a Vaillant ecoFit pure 830 which developed the f. I cover a large part of South Yorkshire including most of Sheffield, Rotherham and Barnsley. POTTERTON Performa 24 Eco HE boiler pdf manual download. Condensate comes out as per normal Checked and Nov 23, 2023 · If a condensate pipe is leaking from a fitting inside the house then this could be dangerous. Any other external leaks to blr. A discharge pipe connected to the condensate trap sends held water out of the property. Dirty Condensate Trap/Drain Over time, dirt, debris, and mineral buildup clog the condensate trap and drain line. They can range from ignition problems and sensor faults to low pressure or circulation issues. Cheap easy repair, get it done quickly before it rots the casing. Expert advice on fixing blockages, fixing leaks, and preventing freezing. Boilers come with an important component named condensate trap. Learn about different types of traps, essential maintenance tips, and key malfunction signs to watch for. It 's about two years old a fires up fine and runs as expected except when switched off and cooled down it drips water from the bottom of the flue pipe that vents to the outside . Everything was ok but the pressure suddenly dropped with lots of water flowing out through the condensate trap. We aim to keep prices low and supply your replacement Baxi 5139810 Condensate Trap for next day delivery so you can complete your repair. Emptied water ,heating came back on and then condensate trap fill back up and heatings goes off, but boilers green light is on to Jun 17, 2015 · After spending a few hours on Google searching and reading posts/articles, I still couldn't find the solution for the problem I'm having. It is leaking at the back of the boiler and is a very slow drip. Also for: Solo he a range, Solo he a series, Solo 24 he a, Solo 30 he a, Solo 12 he, Solo View and Download Baxi Solo HE IE Series installation & servicing instructions manual online. I did empty this when I first had the issue (using the threaded plug on the bottom of the boiler) - but it has been working since. A condensing boiler creates condensate wastewater which is created from the flue gases. Dec 6, 2009 · I am scratching my head over a condensate drain/trap issue with our ICP 90+ efficiency furnace. We aim to keep prices low and supply your replacement Baxi 5142128 CONDENSATE TRAP for next day delivery so you can complete your repair. Jul 25, 2024 · Regular maintenance and monitoring of common issues like low boiler pressure, frozen condensate pipes, and water leaks can help maintain the efficiency and longevity of Baxi boilers. Boiler is working fine otherwise. Nov 6, 2023 · What I think is the condensate connection on our Baxi Solo 24 HE A boiler is leaking, at quite a rate. Contact a qualified Service Technician to inspect the unit and condensate line View and Download Baxi Solo 12 HE installation and servicing instructions online. Discover common issues like clogs and leaks, and find tips for preventative care to avoid costly repairs. If it’s malfunctioning, replace the pump. JA: How long has this been going on with your Baxi pipe? What have you View and Download Baxi 800 System 2 18 installation and service manual online. View and Download Baxi 600 Combi 2 Series installation and service manual online. I reseated and tightened the yellow nut and that didn't help. If condensate is allowed to freeze in the line or if the line is obstructed in any other manner, condensate can exit from the boiler condensate trap, resulting in po Note: e authority having jurisdiction. I can get at the drain plug on the right side but if I open it and drain that side, maybe dislodge some of the debris, do I need to then refill it somehow before next running the boiler? If anyone could provide a Nov 4, 2019 · The condense trap and pipe actually come straight out of a heat exchanger, so if the heat exchanger cracks, pin holes, it will cause system water or mains water if combi side perished, to run into condense pipe. Promax SL Series Condensing Central Heating Boiler. The assembly consists of a condensate line, pump, trap, and drain pipe. This article will guide you through identifying common steam trap issues and troubleshooting them to keep your system running efficiently. Introduction to Condensing Boilers During the heat production phase, the condensing boiler produces many liters of condensate; in winter, it is estimated to produce more than […] Oct 3, 2023 · Is your boiler's condensate pipe blocked? No need to worry; in this article, I will tell you how to fix the problem so that you can enjoy uninterrupted heating. Also for: 624 combi 2, 630 combi 2, 636 combi 2. In this guide, we Baxi 5111451 CONDENSATE TRAP ASSEMBLY. Baxi 5142128 CONDENSATE TRAP. Mar 2, 2025 · Filling loop leaking Flue leaking water A boiler flue leaking water is typically a sign it’s not fitted correctly. A blocked or faulty trap can overflow and appear as a leak underneath. Solution: Turn off the water heater and shut off the gas or electrical supply. Mar 2, 2025 · Learn how to unblock a blocked boiler condensate pipe from a full-time boiler repairer. Our dedicated team is here to assist you in Oct 4, 2020 · Our panel of experts have shared their top tips on how to fix a boiler that is leaking from the bottom and they might just save you a big outlay on repairs. Jan 9, 2020 · Thanks - sorry I forgot to add the type (Baxi duo tec Combi). I opened it up and found that the leakage occurred through the pan separating the lower controls/pump compartment from the upper fire chamber and expansion tank portion. Mar 2, 2025 · Learn what you can do when your Baxi boiler is leaking water from a full-time gas engineer and potentially fix your own leaky boiler. Steam traps play a crucial role in maintaining the efficiency of steam systems by removing condensate, air, and other gases without losing valuable steam. If you can't locate your specific product or need assistance, don't hesitate to Contact Us. Learn how to install, maintain, and maximize the function of this essential component, ensuring your HVAC system runs smoothly. Also for: Solo 18 he, Solo 15 he, Solo 24 he, Solo 30 he. Sep 24, 2023 · Detailed Discussion of Common Causes 1. I fitted a new condensate trap which stopped the leak. Solo HE boiler pdf manual download. If the pump isn’t turning on, ensure it’s receiving power. Set pressure when system cold. Jun 14, 2025 · Identify and repair Navien condensate trap leaks with our guide. 3. PART NUMBER : 5111978. 2 bar, i refilled the system and away it went, i noticed yesterday that there was water on the floor below the boiler and noticed that water was leaking from a small hole located behind the Steam Trap Testing & Troubleshooting Guide Steam trap troubleshooting is a necessary step in diagnosing problems that will arise at some point in the life cycle of your steam system. uk How to clean, remove / refit condensate syphon / trap Baxi 800 / 600 boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. You will probably need to clean out the trap and check that water flows away when poured into the waste pipe. Is this a regular fault and do you have any remedies please? JA: How old is your Baxi boiler? Where does the leak seem to be coming from? Customer: Brand new and appears to come from the flange somewhere underneath Mar 25, 2024 · Suffering from a blocked condensate pipe? No need to worry! Read our guide to learn how to fix a blocked boiler condensate pipe so that you can stay warm. They found the Leak was coming from the top of the boiler as the condensate pipe was blocked. Pa). Verified purchase: YesCondition: NewSold by: adlinkuk by eventersworld Oct 14, 2020 Remove the blanking cap, and using the elbow supplied, connect the condensate drain pipework to the boiler condensate trap outlet pipe. Wall Mounted Powered Flue Condensing Boiler Gas Fired Central Heating Unit. 6. COMMON FAULT. co. To clean a Carrier furnace condensate trap, follow these steps: turn off the furnace, locate and remove the trap, clean it thoroughly using a mixture of water and vinegar, rinse the trap, and reinstall it back into the furnace. Following the instructions in the service manual I managed to remove the condensate trap, clean it out and re-fit it successfully. The condensate trap holds discharge that accumulates in the primary heating or cooling system caused by changes in pressure and temperature. I could not feel any dampness around the connection onto the bottom of the heat exchanger. Ensure no flue gas is leaking from the condensate drain tubi from the opening, this indicates a dry condensate drain trap. LEAKING BAXI COMBI BOILER AGAIN! Blackpool Boiler Installations 629 subscribers Subscribed The condensate drain outlet/trap needs periodic cleaning. ? My boiler is a Baxi Solo 15 HE. Oct 25, 2003 · Mine also leaked condensate but it turned out to the condensate trap which was bunged up with debris. Followed the flow chart,suggested replacing fan or wiring,took out and cleaned and dried the condensate trap,worked a treat. This seemingly insignificant part is capable of bringing your Navien boiler to its knees. Prevent clogs and optimize your air conditioner's performance with tips and insights in our comprehensive installation and function guide. Discover the ultimate guide to RectorSeal's EZ Trap for HVAC systems. 800 System 2 18 boiler pdf manual download. I have had a few of these and the condensate pipe work that have leaked slowly, but this would usually only show up when the boiler is running. Jun 3, 2025 · The intense heat from the exchangers will transform exhaust gas into liquid condensation, which is collected by a condensate pump. I presume there is some sort of leak in the main heat exchanger, allowing the water to drain out At ROMA Heating & Cooling, we specialize in Baxi boiler leak troubleshooting in Greater Vancouver, helping homeowners, property managers, and strata organizations diagnose and repair leaks quickly and professionally. Important Information! This content is for the purpose of gas safety registered heating engineers only. The condensate trap or discharge pipe is blocked and condensate is overflowing. Read how to fix leaks and find out who to call for support. I am pretty sure it is Lennox drain trap Cat # : 61M35 | Model/Part #: LB-96382A. Feb 18, 2008 · new boiler fitted by another installer yesterday, but he's away on holiday. We aim to be the cheapest and easiest Baxi spares supplier for, 5111451 CONDENSATE TRAP ASSEMBLY. Main Combi 24 HE boiler pdf manual download. Of course, leaking water of any kind is not ideal in or around your home, leaking acidic water can cause more damage if it lands on something susceptible to corrosion. Introduction It has come to the attention of Baxi Heating UK Limited (Baxi) that on specific heat only boilers manufactured with a condensate trap positioned on the outside of the boiler, an unusual combination of factors occurring simultaneously (fault on fault condition) could give rise to a safety concern. If condensate is allowed to freeze in the line or if the line is obstructed in any other manner, condensate can exit from the boiler condensate trap, resulting in potential water damage to property. Water at PRV terminal (safety pipe going outside). If this one lasts that long I’ll be happy! Simple to fit and should stop the water leak we had from our boiler. My condensate pipe is leaking water and it is not frozen, My condensate pipe is leaking water and it is not frozen, can you help please. Is your boiler not working? Do you know a boiler condensate trap requires regular cleaning to retain the boiler efficiency and prevent potential problems?The Here is our engineer showing how to clean the condensate trap. Mar 30, 2024 · Additional Reasons For Leaking A clogged drain line is the most common, but it’s not the only reason you may have water dripping or leaking. Baxi 5111714 Condensate Trap Kit - Solo/Combi/Barcelona Part No: 1117812 / MPN: 5111714 Find replacement condensate traps for Worcester, Ideal and Baxi boilers. If your Navien condensate trap is leaking, Apr 30, 2020 · Hi Hoping someone can give me some advice, My elderly mother had a Baxi 630 Comb Boiler fitted in October 2019 , on April 22nd this year it started to leak so she had a Baxi engineer out who said it was the Condensate trap fitted a new one and it worked fine then yesterday she got another leak The water that travels through a condensate pipe is slightly acidic, which is why the condensate pipe needs to be plastic because metal piping would corrode. There is a specific run length to the condensate drain pipe before the pipe size needs to be increased. We aim to keep prices low and supply your replacement Baxi 710006502 CONDENSATE TRAP BODY for next day delivery so you can complete your repair. 105 HE boiler pdf manual download. customers heating comes on then hour later it goes, found condensate trap full of water. This should be emptied/cleaned at each annual service. Apr 29, 2020 · Hi Hoping someone can give me some advice, My elderly mother had a Baxi 630 Comb Boiler fitted in October 2019 , on April 22nd it started to leak so she had a Baxi engineer out who said it was the Condensate trap fitted a new one and it worked fine then today she got another leak she's phoned them again but they can't get to her till Friday , she spoke to a engineer on the phone who said Mar 28, 2019 · I have a Greenstar 30CDi Combi boiler that is needs to be topped up twice a day. These codes are designed to help you quickly identify what’s gone wrong. Date issued: August 2017. And unfortunately, if your boiler condensate pipe is leaking, it can be challenging to get it fixed. Mar 10, 2023 · A leaking boiler condensate pipe can be a very frustrating problem to deal with. So you have the manufacturer’s instructions for your appliance? Nov 20, 2011 · Hi WE just come to fire up out combi boiler due to the cold weather. I recently noticed the condensate trap is leaking. Inspect the Sep 19, 2018 · Signs of condensate leaking from pipe on Vaillant ecoTEC Pro combi boiler I am located in Elsecar, Barnsley, South Yorkshire. Given that its a duotec I may be wrong but i think they have a ten year warranty, Give Baxi a call and find out if you can get a warranty call out. Condensate Pump If your furnace uses a condensate pump, it can clog or the pump can fail causing water to leak. I haven't noticed it dripping when the boiler isn't running but as I've mentioned in a previous thread before we have ongoing issues with water appearing in the 'top' chamber behind the main removable front cover. Jan 13, 2007 · If it really lets more than a few cc when its off the suspicion would be an internal leak inside the boiler. Clean the pump to remove any buildup. This wastewater needs to run back into the boiler condensate trap via the flue which is why the flue needs to be pointing slightly up and away from the boiler. The pressure runs down to zero bar. View and Download Potterton Promax SL range installation & service instructions manual online. (I replaced it with a different material (clear vinyl) because that Looking for affordable and hassle-free Baxi spare parts for your CONDENSATE TRAP BODY - 720763701? Look no further! We strive to be your go-to supplier for genuine Baxi spares. T Mend > Home Heating Systems Condensate trap leaking on Heatline Vizo boiler? The condensate trap has a steady drip from the side when the hot water is running. View and Download Baxi Solo HE installation & service instructions manual online. Feb 12, 2011 · visited a Baxi 50 he plus the other day,debris in the trap at the top near the contacts was trapping damp and giving a ''fan lockout'' signal. The leak is a constant Nov 29, 2023 · On first using the heating we had water dripping out of the bottom of the boiler so called a plumber. 1. It is simple to defrost your condensate pipe. If this one lasts that long I’ll be happy! Aug 23, 2017 · Baxi and Potterton Heat Only - Condensate Trap. 6 days ago · 5. Is it clean water that Mend > Home Heating Systems Condensate trap leaking on Heatline Vizo boiler? The condensate trap has a steady drip from the side when the hot water is running. However, faulty steam traps can lead to energy loss, equipment damage, and decreased system performance. Locate the condensate drain (typically near the bottom of the unit). I took the cover the boiler yesterday to find Oct 18, 2024 · Discover the causes of common Baxi boiler problems and how to fix them. Gas and electrical safety If you’ve noticed your standard or combi boiler leaking, the first steps to take are to examine the boiler itself, and all surrounding pipework. Baxi 5139810 Condensate Trap. We thought it might be the condensate pipe backing up as it was quite dodgy but replacing brand new with a vertical drop In Condensing Boilers, this component is placed between the primary heat exchanger and the drain line, and it prevents the exhaust gases from discharging into the condensate drain pipe. Keeping your Carrier furnace in top condition is essential to maintain optimal heating and cooling efficiency in your home. Jan 14, 2019 · Hello, I have a Lennox G51MP Furnace. The plumber who fitted it thinks there is an air lock in the drain pipe, but I've taken the pipe off and blown it through (as he suggested). Ensure your furnace runs smoothly and safely by understanding the Nov 3, 2024 · Potterton condensate trap Replaced cracked and leaking trap that was 15yrs old and came with the boiler. The see through plastic condensate trap (7683856) is leaking, drip by drip, at the bottom flange where it sits on the gasket seal. The condensate trap is rectangular and has seperate chambers, the left hand side is half full and the right hand side appears to be empty. May 15, 2018 · I have been having an ongoing issue with ignition lockouts (Red light ON, Flame light OFF, Mains light ON) on my Baxi solo boiler and according to the service manual fault finding flow chart, looks likely to be the electrodes or condensate trap. One of my installs from 6 years ago,good customer ,glad i didnt change the fan. Check the pump for proper operation. Steam trap failure is caused by improper removal of the condensate. Oct 17, 2008 · 14 May 2020 Madrab R Leak from Condensation Trap - Ideal Isar Boiler Robertspaw 1 Feb 2011 Plumbing and Central Heating Replies 1 Views 2K 1 Feb 2011 May 3, 2007 · Hi, Hopefully someone can shed some light on a boiler problem I have. When the steam trap shows signs it can no longer remove condensate Mar 30, 2016 · Sounds like its the heat exchanger leaking into the condensate. Potterton Promax SL range boiler pdf manual download. A condensate pump will take excess moisture from any AC unit or furnace and collect it in a drain trap. (Clear plastic box on bottom rhs of blr) Chamnging this trap would have no effect whatsoever on your system pressure. Search our directory to find boiler repair services near you. After the plumber went we put the heating on again and water was still dripping out of the bottom of the boiler. Dec 17, 2023 · Faulty seals: Seals deteriorate over time, and your Baxi boiler might have worn-out or cracked seals, allowing water to escape. dgooqumnzjpfwzqhnkiuoulsinqykeniiwfckczfnlcntcgfxqof